Higher feedwater temperature increases the boiler output
Higher feedwater temperature leads to increased boiler output with reduced fuel consumption.
The boiler’s capacity is stated in ‘from and at’ rating which shows the amount of steam in kg/hr which the boiler can create ‘from and at 100°C, at atmospheric pressure. Thus, the closer the feedwater temperature to 100°C, the closer the output generated to rated capacity.
In most plants, feedwater temperature is rarely maintained at 100°C. It is typically ambient or slightly higher than ambient. This leads to a poor steam to fuel ratio and lowers boiler capacity.
The following formula helps calculate the steam output from the boiler:
Steam output = Boiler rating (TPH) x 540 Kcal/kg / (energy to be added) Kcal/kg
Where, Energy to be added = (Total enthalpy at boiler operating pressure – Feedwater temperature)
540 Kcal/kg = Latent heat of evaporation for water at atmospheric pressure
Illustration:
Consider a 10 ton/hr capacity oil fired boiler with an 80% operating efficiency.
Feedwater Temp. | Feedwater Temp. | |
Maximum steam | 8.71 tph | 9.64 tph |
Steam to fuel ratio | 12.9 | 14.28 |